More about MDMA-QTest (Advanced)
With this drug test you can also measure other psychoactive substances such as 2C-B, amphetamine (speed), methamphetamine (crystal meth), MDA, PMMA, or PMA.
Why are PMMA or PMA extremely dangerous substances?
PMMA and PMA are almost identical to MDMA in bodily effects, but they are far more dangerous. This is because PM(M)A is known to be more potent than MDMA as it has a slower onset of action and a longer duration of effects. While under the assumption of the immediate effects of MDMA, this leads the user to potentially take higher doses to achieve the desired effect. In case with PM(M)A, overdoses occur very quickly. The difference in dose at which effects occur and at which an overdose occurs is extremely small. Due to the high toxicity, taking a little too much can already lead to a rapid increase in body temperature that ultimately leads to organ failures, seizures, and even death.
Short information
Mobile rapid testing to determine the concentration of MDMA in pills and crystals with additional detection of auxiliary materials.
- Fast detection in only 15 minutes.
- Detection ranges between 40 and 320 mg of active substance content.
- Additional detection of 2C-B, amphetamine, methapmetamine, MDA, PMMA, or PMA.
- Evaluation can be done with the naked eye.
- Testkit is meant for single-use only.
Storage and shelf life:
Cool storage of the reagents at 2°C to 8°C, with protection from direct sunlight (e.g. refrigerator), guarantees a 12-month shelf life for the consumables if stored properly.
Content
- 1x Pair of protective gloves.
- 1x Extraction vessel with a 2-phase purification, with a black lid.
- 1x Dropper bottle with developer, with a green screw top.
- 1x Large glass jar with detection reagent, with a white screw cap.
- 1x Small glass jar and detection reagent, with a blue lid.
- 1x Small glass jar and detection reagent, with a red lid.
- 1x Pipette
- 1x Small ziplock bag.
- 1x Evaluation scale.
- 1x Manual.
Manual in 3 steps
1. Preparation
It is possible to test MDMA in both crystals and pill form. If you are testing crystals, take 30mg as a test material and 50mg for pills.
Clean your hands and put on the safety gloves. Remove the contents from the box and put them in the destined holes in the box for easy filling throughout the testing process. Now make sure the pill is clean from the outside, brush any impurities gently off with the delivered piece of sandpaper, if necessary. Take 50 mg if you have powder or 20 mg if you have crystals as starting material. If you are testing crystals, it is still necessary to crush them beforehand.
2. Extraction
Put the test material in the extraction vial with the black top and shake well for 5 seconds. This causes the content to separate from each other. Make sure that the surface of the 2-phase purification liquid is clear (if not, you can tilt the bottle a little to get rid of the bubbles).
Then, use the pipette to extract some of the lowest liquid in the vessel. Make sure you put your pipette in the middle part of it to ensure you are not taking anything from the top part or any debris from the bottom.
Drop 2 droplets back into the same vessel and drop 3 droplets in each reagent solution (all three of them). If there is not enough, repeat the previous step where you take some of the middle part of the bottom layer of liquid.
Filling the large glass vessel → Close the large glass vessel with white screw cap and give it a quick shake. Put a timer on for 12 minutes.
Filling the two smaller vessels → Open the dropper bottle with developer and put 14 drops in it. Close it and rotate it 2 to 4 times.
Now wait until the 12 minutes have passed.
3. Detection & Evaluation
Compare the large glass vessel with the evaluation scale and determine concentration.
For the extender detection use the small vessels, the color path chart and the big reagent vial. On the color path, there is a dedicated column for the small glass vessel with the blue lid and one row for the vessel with the red lid. Match the small vials in the row of MDMA/MDA.